F.A.Q. по ремонту и обслуживанию копиров

         

The heater film has gone


Код ошибки

Описание

E0

Heater problem

E1



The heater film has gone off center. Turn machine off & on, make sure it's level etc.

E2

Scan problme

E6

Exposure lamp or exposure lamp sensor


Canon 10, 24, 115, 14, NP112, PC3


Код ошибки

Описание

E0

Heat lamp

E2

Scanner


Fuser problem. Low temperature. Lamp,


Код ошибки

Описание

E2

Scanner

E0

Heat lamp

D030

Total counter or DC controller

E00

Heater (Press SW301 twice to reset)

E001

Over temperature

E010

Drum drive clock pulse

E202

Scan home position

E204

Registration switch (scan problem)

E210

Lens home

E221

Lamp regulator or DC controller

E400

Document feed problem (Check circuit breaker)

E500

Sorter (Check circuit breaker)

E000

Fuser problem. Low temperature. Lamp, thermal switch, AC driver

E001

Fuser problem. High temperature. Triac, AC driver, pinched wire

E004

Fuser problem

E053

Sorter

E030

Counter

E202

Scan

E210

Lens

E221

Exposure lamp regulator board, thermal fuse, exposure lamp

E400

ADF

E500

Sorter

E710

DC controller (main board)

E001

Heater problem


thermoswitch or heat


Код ошибки

Описание

E0

Thermistor/ thermoswitch or heat lamps

E1

Sorter

E2

Scanner home

E3

Scanner return

E4

Right front door/main motor

E5

Lens home

E6

Lamp regulator

E8

Counter wire


High fuser temperature. Shorter fuser


Код ошибки

Описание

E0

Thermistor, thermal switch, heat

E1

Sorter, scanner home

E2

Motor, clock pulse

E3

Scan problem

E4

Lens home

E5

Lamp regulator/document sensor

E6

Motor control

E7

Total counter

E8

Lamp regulator

E9

Copyboard drive motor/board

ED

Motor control PCB

EE

DC controller on motor

E001

High fuser temperature. Shorter fuser thermistor

E030

Total counter disconnected or open

E202

Scan problem

E210

Lens problem

E221

DC power supply, lamp regulator board or main board

E400

Document feeder board problem

E500

Sorter board problem

E000

Low fuser temperature


DC controller on


Код ошибки

Описание

E0

Thermistor, thermal switch, heat

E1

Sorter, scanner home

E2

Motor, clock pulse

E3

Scan problem

E4

Lens home

E5

Lamp regulator/document density sensor

E6

Motor control board

E7

Total counter

E8

Lamp regulator

E9

Copyboard drive motor/board

ED

Motor control PCB

EE

DC controller on motor


Canon 210, 300


Код ошибки

Описание

E0

Heat problem

E1

Sorter

E2

Scanner

E4

Drum drive

E5

Lens drive

E6

Exposure lamp

E7

Mirror sensors


Clock pulse or open RF


Код ошибки

Описание

E0

Fuser

E1

Sorter

E2

Scan home

E3

Scan

E4

Clock pulse or open RF door

E5

Lens position

E6

Exposure lamp, fuse 2

E8

Counter


No problem. Means that the


Код ошибки

Описание

C

No problem. Means that the machine is correcting the fuser film tracking

CC

Drum must be changed. Could be the drum serial number is identified by the logic as being non-compatible to that particular copier

E000

Low fuser temperature

E001

High fuser temperature

E002

High fuser temperature

E003

Erratic fuser temperature

E007

Fuser film off track and will not repair itself

E010

Main drive problem

E030

Counter problem

E064

Scan problem, or power supply

E202

Scan problem

E210

Lens drive problem or lens sensor

E220

Exposure lamp stays on or off

E240

DC controller (main board) or composite power supply

E261

Zero cross problem. Power frequency or composite power supply

E400

Communication problem between boards

E803

24 volt problem

E0

Fuser problem

H

Fuser overheat


High fuser temperature. Shorter fuser


Код ошибки

Описание

E001

High fuser temperature. Shorter fuser thermistor

E030

Total counter disconnected or open

E202

Scan problem

E210

Lens problem

E221

DC power supply, lamp regulator board or main board

E400

Document feeder board problem

E500

Sorter board problem

E000

Low fuser temperature


Total counter or DC


Код ошибки

Описание

D030

Total counter or DC controller

E00

Heater (Press SW301 twice to reset)

E001

Over temperature

E010

Drum drive clock pulse

E202

Scan home position

E204

Registration switch (scan problem)

E210

Lens home

E221

Lamp regulator or DC controller

E400

Document feed problem (Check circuit breaker)

E500

Sorter (Check circuit breaker)


Fuser problem. Low temperature. Lamp,


Код ошибки

Описание

E000

Fuser problem. Low temperature. Lamp, thermal switch, AC driver

E001

Fuser problem. High temperature. Triac, AC driver, pinched wire

E004

Fuser problem

E0053

Sorter

E030

Counter

E202

Scan

E210

Lens

E221

Exposure lamp regulator board, thermal fuse, exposure lamp

E400

ADF

E500

Sorter

E710

DC controller (main board)


Main motor, motor board, clock


Код ошибки

Описание

E000

Fuser problem

E010

Main motor, motor board, clock pulse

E030

Counter

E050

Duplex side to side problem

E051

Crossway registration

E200

Scan problem

E200

Scan reverse sensor or scan

E202

Scan return problem

E204

Document sensor, scan reverse sensor or scale

E210

Lens problem

E220

Lens

E220

Blank lamp open or lens home problem

E240

DC controller

E400

Document feeder board problem or document feeder interface problem

E500

Sorter

E620

Editing problem


Fuser temp low. Heat lamp,


Код ошибки

Описание

E000

Fuser temp low. Heat lamp, thermoswitch, thermistor, SSR

E001

Fuser temperature too high or shorted thermistor

E002

Fuser temperature too low

E003

Fuser temperature too low

E004

SSR, or lamp reg. board

E010

Drive problem

E022

DV unit switching problem

E030

Counter not working/open

E202

Scan problem. Scan sensor, scan motor

E204

Scan problem. Scan sensor, scan motor

E210

Lens problem. Lens sensor, lens motor

E220

Exposure lamp

E240

DC controller (main board)

E400

RDF circuit board

E401

RDF pickup motor drive

E402

RDF belt motor drive

E403

RDF feed drive problem

E404

RDF exit motor

E411

RDF sensor problem

E500

Sorter board problem

E510

Sorter feed motor

E512

Sorter delivery motor

E514

Sorter delivery motor

E520

Sort stack motor

E530

Vibrator motor

E531

Stapler motor

E535

Vibrator motor

E540

Shift problem

E541

Shift problem

E710

DC controller

E711

DC controller

E712

DC controller. Document feeder board or cable

E800

Auto shut off relay


Blank lamp open or lens


Код ошибки

Описание

E000

Fuser problem

E010

Drive

E030

Counter

E050

Duplex side to side problem

E051

Duplex side to side problem

E200

Scan problem

E202

Scan return problem

E204

Scan

E210

Lens problem

E220

Blank lamp open or lens home problem

E240

Bad DC controller

E400

Document feeder board problem or document feeder interface problem

E500

Sorter

E620

Editing problem


Low fuser temperature. Heat lamp,


Код ошибки

Описание

E000

Low fuser temperature. Heat lamp, thermoswitch, thermofuse, thermistor, SSR

E001

High fuser temperature. Thermistor, SSR, pinched wire

E002

Low fuser temperature. Same as E002

E003

Same as E000/E001

E010

Same as E002

E022

Motor drive problem

E030

Counter

E202

Scan motor, sensor

E204

Scan motor, sensor

E210

Lens motor, sensor

E220

Exposure lamp

E240

DC controller (main board)

E401

Pickup drive problem (might be Doc. Feeder)

E402

Document belt drive problem

E404

Exit motor (document feeder)

E411

Document sensor (document feeder)

E500

Sorter/machine communication problem

E510

Sorter drive problem

E530

Sorter home sensor

E531

Stapler unit swing sensor

E540

Sorter cam sensor

E541

Sorter cam sensor

E710

DC controller (main board)

E712

DC controller or document feeder board


Main motor, motor board, clock


Код ошибки

Описание

E000

Fuser problem

E010

Main motor, motor board, clock pulse

E030

Counter

E050

Duplex side to side problem

E051

Crossway registration

E200

Scan problem

E202

Scan return problem

E202

Scan home sensor or home scan

E204

Document sensor, scan reverse sensor or scale

E210

Lens

E220

Blank lamp open or lens home problem

E240

DC controller

E400

Document feeder board problem or document feeder interface problem

E500

Sorter

E620

Editing problem


Low fuser temperature. Heat lamp,


Код ошибки

Описание

E000

Low fuser temperature. Heat lamp, thermoswitch, thermofuse, thermistor, SSR

E001

High fuser temperature. Thermistor, SSR, pinched wire

E002

Low fuser temperature. Same as E002

E003

Same as E000/E001

E010

Same as E002

E022

Motor drive problem

E030

Counter

E202

Scan motor, sensor

E204

Scan motor, sensor

E210

Lens motor, sensor

E220

Exposure lamp

E240

DC controller (main board)

E401

Pickup drive problem (might be Doc. Feeder)

E402

Document belt drive problem

E404

Exit motor (document feeder)

E411

Document sensor (document feeder)

E500

Sorter/machine communication problem

E510

Sorter drive problem

E530

Sorter home sensor

E531

Stapler unit swing sensor

E540

Sorter cam sensor

E541

Sorter cam sensor

E710

DC controller (main board)

E712

DC controller or document feeder board


Bind or load on main


Код ошибки

Описание

E000

Low fuser temperature

E001

High fuser temperature

E010

Main motor clock pulse

E011

Bind or load on main motor

E020

No TF for 3 minutes

E030

Copy counter

E050

Duplex unit

E201

Scan motor

E203

Scan motor

E210

Lens home

E240

DC controller

E241

DC controller

E320

CCD

E400

DC controller, 24V

E500

DC controller, 24V

E510

Finisher feed motor

E520

Stacker motor

E530

Guide plate shift motor

E531

Stapler motor

E620

DC controller, edit board


High fuser temperature or shorter


Код ошибки

Описание

E000

No fuser heat

E001

High fuser temperature or shorter thermistor

E002

Low temperature or bad thermistor

E003

Fuser problem

E004

Bad SSR (heat staying on)

E010

Drive

E020

Black toner motor

E030

Counter

E080

Interface problem with color unit

E081

Vertical drive motor

E082

Horizontal drive motor

E083

Color unit sensor on right

E084

Color unit sensor on left

E085

Color unit release sensor or release or solonoid

E086

Color unit claw release

E089

Laser problem

E100

Laser problem

E110

Laser motor

E140

Laser

E202

Scan

E203

Scan

E204

Scan

E210

Lens

E223

Color unit filter drive motor

E240

DC controller

E401

RDF pickup motor

E402

RDF belt motor

E403

RDF feed motor

E411

RDF document sensor

E500

Sorter-Copier communication error

E510

Sorter drive

E512

Sorter drive

E513

Sorter drive

E514

Sorter drive

E520

Top limit sensor or stack sensor

E530

Sorter home sensor

E531

Stapler home sensor

E535

Stapler swing sensor

E540

Stack shift sensor

E660

IC card

E710

DC controller

E711

DC controller

E714

DC controller

E800

Power off circuit


Bind or load on main


Код ошибки

Описание

E00

Low fuser temperature

E001

High fuser temperature

E010

Main motor clock pulse

E011

Bind or load on main motor

E020

No TF for 3 minutes

E030

Copy counter

E050

Duplex unit

E201

Scan motor

E203

Scan motor

E210

Lens home

E240

DC controller

E241

DC controller

E320

CCD

E400

DC controller, 24V

E500

DC controller, 24V

E510

Finisher feed motor

E520

Stacker motor

E530

Guide plate shift motor

E531

Stapler motor

E620

DC controller, edit board


Sorter to DC control interface


Код ошибки

Описание

E000

Low fuser temperature

E001

High fuser temperature

E002

Low fuser temperature

E003

Low fuser temperature

E010

Drive

E030

Counter

E080

Color change board problems

E081

Color horizontal motor problem

E082

Color horizontal motor problem

E083

Color problem in vertical direction

E084

Color problem in vertical direction

E085

Color problem in vertical direction

E086

Color unit claw release problem

E089

Color change incomplete

E100

Laser problem

E110

Laser motor problem

E140

Laser unit

E203

Scan drive problem

E210

Lens not home or won't leave home

E240

DC controller

E401

Document feeder pick up motor

E402

Document feeder belt motor

E403

RADF feed motor

E404

Document feeder motor

E411

Document feeder sensor

E500

Sorter to DC control interface problem

E510

Stapler/sorter motor

E530

Stapler swing motor

E531

Stapler swing motor

E540

Sorter bin motor

E541

Sorter bin motor

E710

DC controller

E711

DC controller

E712

DC controller to document feeder interface problem


Canon 6012F


Код ошибки

Описание

C

No problem. Means that the machine is correcting the fuser film tracking

CC

Drum must be changed. Could be the drum serial number is identified by the logic as being non-compatible to that particular copier

E000

Low fuser temperature

E001

High fuser temperature

E002

High fuser temperature

E003

Erratic fuser temperature

E007

Fuser film off track and will not repair itself

E010

Main drive problem

E030

Counter problem

E064

Scan problem, or power supply

E202

Scan problem

E210

Lens drive problem or lens sensor

E220

Exposure lamp stays on or off

E240

DC controller (main board) or composite power supply

E261

Zero cross problem. Power frequency or composite power supply

E400

Communication problem between boards

E803

24 volt problem

EO

Fuser problem

H

Fuser overheat



Fuser temperature not rising at


Код ошибки

Описание

E000

Fuser did not heat up

E001

Fuser temperature too high

E002

Fuser temperature not rising at correct pace

E003

Fuser temperature drops

E004

SSR shorted

E210

Lens home problem

E212

Lens home problem

E220

Exposure lamp problem

E224

Blank shutter home problem

E240

DC controller or composite power supply problem

E400

Data communication problem

E401

Pickup motor problem

E402

Belt motor problem

E403

Feeder motor

E404

Delivery motor

E411

Document detect sensor

E500

Communication problem with copier

E510

Feeder motor

E530

Home sensor

E531

Staple swing sensor problem

E540

Bin shift motor rotation problem

E541

Bin motor

E710

DC controller

E711

Document feeder IC failure

E716

Cassette feed IC failure

E800

Auto power-off circuit problem

E901

Cassette feed motor

E902

Paper guide home sensor problem


Fuser did not heat up.


Код ошибки

Описание

E000

Fuser did not heat up. Lamp, thermal switch, thermistors, connections, AC driver, DC controller, SSR, etc

E001

Fuser temperature too high. Same possibilities as E000, as well as shorted wire

E002

Fuser temperature not rising at correct pace. Same possibilities as E000

E003

Fuser temperature drops. Same as E003

E004

Fuser problem. AC driver, SSR bad, wire shorted

E010

Drive problem. Main motor, gears, etc

E030

Total counter

E064

Composite power board or DC controller

E065

Composite power board or DC controller

E202

Scan motor or scan sensor problem. Panel locked with no Код ошибки. Scan motor problem

E203

Scan problem or scan sensor

E204

Scan problem or scan sensor

E210

Lens sensor or motor problem

E212

Lens sensor or motor problem

E220

Exposure lamp or exposure lamp regulator board

E224

Blanking shutter motor or sensor

E240

DC controller or composite power supply problem

E244

DC controller

E400

RDF to copier communication problem

E401

RDF Pickup motor or pick up sensor

E403

RDF feed motor or pulse sensor

E404

RDF delivery motion problem

E404

RDF delivery motor problem

E411

RDF tray sensor or registration sensor

E500

Sorter main board or communication with copier

E510

Sorter feed motor

E530

Sorter guide bar motor

E531

Sorter stapler motor

E540

Sorter bin shift motor

E541

Sorter bin motor

E550

Sorter power supply

E710

DC controller

E711

DC controller

E712

Document feeder IC failure

E716

DC controller. Sorter

E800

Auto power off function (DC controller)

E901

Pedistal motor

E902

Jogger side plate sensor or motor


Fuser did not heat up.


Код ошибки

Описание

E000

Fuser did not heat up. Lamp, thermal switch, thermistors, connections, AC driver, DC controller, SSR, etc

E001

Fuser temperature too high. Same possibilities as E000, as well as shorted wire

E002

Fuser temperature not rising at correct pace, same possibilities as E000

E003

Fuser temperature drops. Same as E000

E004

Fuser problem: AC driver, SSR bad, wire shorted

E005

Fuser cleaning web, or problem with sensor, lever or connector. Service mode 6 is the probably reset for this

E006

Fuser feed connector

E010

Drive problem. Main motor, gears, etc

E013

Waste toner drive problem, or waste toner sensor switch has been actuated too many times

E015

Pickup motor power supply. Could be bad motor or motor board, or DC controller

E020

Problem with developer unit, toner hopper, hopper motor, connection, sensor or DC controller

E030

Total counter

E031

Option counter or total counter

E050

Holding tray (duplex) home position sensor motor or board

E051

Holding tray (duplex) home sensor motor or board

E202

Panel locked up, but might be no Код ошибки, scan motor problem

E203

Scan problem or scan sensor

E204

Scan problem or scan sensor

E210

Lens sensor or motor problem

E212

Lens sensor or motor problem

E213

Scan lock sensor or lock solenoid

E220

Exposure lamp regulator board

E240

DC controller or composite power supply problem

E243

DC controller

E400

RDF to copier communication problem

E401

RDF pickup motor or pickup sensor

E402

RDF belt motor or pulse sensor

E403

RDF feed motor or pulse sensor

E411

RDF tray sensor or registration sensor

E500

Sorter main board or communication with copier

E510

Sorter feed motor

E522

Sorter push bar motor

E523

Sorter reference wall motor

E524

Sorter multi-guide motor

E525

Sorter bin paper sensor automatic adjustment problem

E526

Sorter bin paper sensor automatic adjustment problem

E530

Sorter guide bar motor

E531

Sorter stapler motor

E532

Stapler motor

E533

Stapler inside paper sensor

E540

Sorter bin shift motor

E550

Sorter power supply

E710

DC controller

E711

DC controller

E712

Document feeder IC failure

E713

DC controller, sorter

E800

Auto power off circuit problem. Main switch or DC controller

E802

Auto power off circuit problem. Main switch or DC controller


the upper fixing roller does


Код ошибки

Описание

E000

After power-on, the upper fixing roller does not reach 100 C within 5 min

E001

The temperature of the upper fixing roller exceeds 230 C for 5 sec or more

E002

After the temperature of the upper fixing roller has exceeded 100 C, it does not reach 180 C within 5 min

E003

After the temperature of the upper fixing roller has reached 180 C, it drops to 100 C or less for 5 sec or more

E005

The length used of the cleaning belt inside the fixing assembly has exceeded a specific value

E012

After the drum motor drive signal has been generated, clock pulses are not generated within 2 sec

E013

After the waste toner feeding screw has become locked, the detecting switch (SW20) is pressed a multiple number of times within a specific period of time

E014

When the fixing motor (M17) is rotating, an error is detected for 2 sec or more

E015

After the pick up motor drive signal has been generated, clock pulses have not been generated within 2 sec

E019

As many as 50,000 have been made after detecting a waste toner full condition

E020

During copying, the toner supply signal is 0', indicating the absence of toner, for 3 min or more. During toner supply sequence at time of installation, the toner supply signal does not go '1' after 6 min or more

E030

After the total copy counter has turned OFF, an open circuit is detected for the total copy counter

E032

After the clock pulse signal reached the IPC communication format of the copier DC controller PCB, the Copy Data Controller-A1 does not detect the signal

E050

While the paper jogging guide motor (M11) drive signal is being generated, the paper guide home position signal (THP) is not generated for 2 sec or more. While the paper jogging guide motor (M11) is being generated, the paper jogging guide home position signal (THP) is generated for two sec or more

E202

The scanner home position signal (SCHP) is not generated within 10 sec after the power switch or the Copy Start Key is pressed

E203

While the scanner motor drive signal is being generated, clock pulses are not generated within 2 sec

E204

The scanner leading edge signal (SCDP1) is not generated within 0.8 sec after the scanner has started to move

E209

The scanner C.F.F. position signal (SCFFP) is not generated within 10 sec after the C.F.F. has been sent

E210

The lens X home position signal (SCFFP) is not generated within 10 sec after the C.F.F. has been sent

E212

The lens Y home position signal (LYHP) is not generated within 9 sec after the power switch or the Copy Start Key is turned ON. The lens Y home position signal (LYHP) is generated for 2 sec or more

E213

In stream reading mode, the scanner original leading edge sensor 2 signal (SCDP2) is not generated for 5 pages continuously

E214

While the scanner cooling fan (FM1, FM10, FM11) is rotating, an error signal is generated for 2 sec or more

E270

In stream reading mode, the scanner leading edge signal(SCDP2) is not generated within a specific period of time after a command has been issued to lock the scanner

E710

At power-on the IPC (Q170) on the DC controller PCB cannot be initialized

E711

After power-on the IPC (Q170) on the DC controller PCB goes out of order

E712

The communication IC on the RDF controller PCB has gone out of order

E713

The communication IC on the sorter control PCB has gone out of order

E715

The communication IC on the C.F.F. controller PCB has gone out of order

E717

The communication IC on the Copy Data Controller-A1 PCB has gone out of order

E800

An open circuit is detected

E801

Current flows from the activation circuit in the absence of the scanning lamp ON signal

E802

The relay (RL3) in the power supply unit does not operate in spite of the auto power-off signal


Toner motor, toner level sensor,


Код ошибки

Описание

E000

Thermistor

E001

SSR

E002

Thermistor, ht. Lamp thermal fuse or SSR

E003

Thermistor, ht. Lamp thermal fuse or SSR

E005

Fuser cleaning belt

E010

Main drive problem

E020

Toner motor, toner level sensor, toner hopper sensor

E030

Counter

E050

Duplex problem

E203

Scan home problem

E210

Lens home sensor

E401

Document feeder paper pickup motor

E402

Document feeder belt clock pulse problem

E403

Document feeder main motor clock pulse problem

E411

Document feeder sensor problem

E500

Sorter/copier interface problem

E510

Sorter motor drive

E530

Sorter home sensor

E531

Stapler swing sensor

E540

Sorter lead cam home sensor

E541

Sorter lead cam home sensor

E710

DC controller board

E711

DC controller board

E712

Document feeder problem


No problem. Means that the


Код ошибки

Описание

C

No problem. Means that the machine is correcting the fuser film tracking.

CC

Drum must be changed. Could be the drum serial number is identified by the logic as being non-compatible to that particular copier.

E000

Low fuser temperature

E001

High fuser temperature

E002

High fuser temperature

E003

Erratic fuser temperature

E007

Fuser film off track and will not repair itself

E010

Main drive problem

E030

Counter problem

E064

Scan problem, or power supply

E202

Scan problem

E210

Lens drive problem or lens sensor

E220

Exposure lamp stays on or off

E240

DC controller (main board) or composite power supply

E261

Zero cross problem. Power frequency or composite power supply

E400

Communication problem between boards

E803

24 volt problem

EO

Fuser problem

H

Fuser overheat


Fuser did not heat up.


Код ошибки

Описание

E000

Fuser did not heat up. Lamp, thermal switch, thermistors, connections, AC driver, DC controller, SSR, etc

E001

Fuser temperature too high. Same possibilities as E000, as well as shorted wire

E002

Fuser temperature not rising at correct pace. Same possibilities as E000

E003

Fuser temperature drops. Same as E003

E004

Fuser problem. AC driver, SSR bad, wire shorted

E010

Drive problem. Main motor, gears, etc

E030

Total counter

E064

Composite power board or DC controller

E065

Composite power board or DC controller

E202

Scan motor or scan sensor problem. Panel locked with no Код ошибки. Scan motor problem

E203

Scan problem or scan sensor

E204

Scan problem or scan sensor

E210

Lens sensor or motor problem

E212

Lens sensor or motor problem

E220

Exposure lamp or exposure lamp regulator board

E224

Blanking shutter motor or sensor

E240

DC controller or composite power supply problem

E244

DC controller

E400

RDF to copier communication problem

E401

RDF Pickup motor or pick up sensor

E403

RDF feed motor or pulse sensor

E404

RDF delivery motion problem

E404

RDF delivery motor problem

E411

RDF tray sensor or registration sensor

E500

Sorter main board or communication with copier

E510

Sorter feed motor

E530

Sorter guide bar motor

E531

Sorter stapler motor

E540

Sorter bin shift motor

E541

Sorter bin motor

E550

Sorter power supply

E710

DC controller

E711

DC controller

E712

Document feeder IC failure

E716

DC controller. Sorter

E800

Auto power off function (DC controller)

E901

Pedistal motor

E902

Jogger side plate sensor or motor


Toner motor, toner level sensor,


Код ошибки

Описание

E000

Thermistor

E001

SSR

E002

Thermistor, ht. Lamp thermal fuse or SSR

E003

Thermistor, ht. Lamp thermal fuse or SSR

E005

Fuser cleaning belt

E010

Main drive problem

E020

Toner motor, toner level sensor, toner hopper sensor

E030

Counter

E050

Duplex problem

E203

Scan home problem

E210

Lens home sensor

E401

Document feeder paper pickup motor

E402

Document feeder belt clock pulse problem

E403

Document feeder main motor clock pulse problem

E411

Document feeder sensor problem

E500

Sorter/copier interface problem

E500

An error is identified in the communication between the sorter and the copier

E510

The clock signal from the motor is absent for 250ms or more

E510

Sorter motor drive

E513

The clock signal from the motor is absent for 250 ms or more

E530

Sorter home sensor

E530

The home position sensor (P17) fails to go OFF when an equivalent of 2560 pulses of the motor drive command has been generated

E531

The stapler unit swing sensor (MS9) fails to go ON within 500 ms after the motor drive command has been generated. MS9 fails to go back OFF within 1000 ms after it has gone on

E531

Stapler swing sensor

E540

The lead cam home position sensor (P12) fails to go OFF within 2000 ms after the motor drive command has been generated. P12 fails to go back ON within 2000 ms after it has gone OFF

E540

Sorter lead cam home sensor

E541

Sorter lead cam home sensor

E710

DC controller board

E711

DC controller board

E712

Document feeder problem


Heater triac, DC controller, AC


Код ошибки

Описание

E000

Heater (Reset by unplugging machine)

E001

Heater triac, DC controller, AC driver (reset by unplugging)

E005

Fuser cleaner belt at end. Replace

E010

Main motor, DC controller or DC driver board

E011

Any motor ( main, scan, cleaner belt, duplex, toner, lens) DC driver, DC controller, duplex driver board

E020

Toner out signal has been sent for at least 3 minutes

E050

Duplex

E203

Scan motor, DC driver, DC controller

E210

Lens home sensor not actuated or won't deactuate

E240

Controller board

E241

Controller board

E242

Controller board

E400

DC controller, Doc. Feeder board, 24V power supply

E500

DC controller, sorter board, 24V power supply


Heater triac, DC controller, AC


Код ошибки

Описание

E000

Heater (Reset by unplugging machine)

E001

Heater triac, DC controller, AC driver (reset by unplugging)

E005

Fuser cleaner belt at end. Replace

E010

Main motor, DC controller or DC driver board

E011

Any motor ( main, scan, cleaner belt, duplex, toner, lens) DC driver, DC controller, duplex driver board

E020

Toner out signal has been sent for at least 3 minutes

E050

Duplex

E203

Scan motor, DC driver, DC controller

E210

Lens home sensor not actuated or won't deactuate

E240

Controller board

E241

Controller board

E242

Controller board

E400

DC controller, Doc. Feeder board, 24V power supply

E500

DC controller, sorter board, 24V power supply


Fuser problem. Temperature too low.


Код ошибки

Описание

E000

Fuser problem. Temperature too low. Heat lamp, thermal fuse or thermoswitch, thermistor, triac etc

E001

Fuser problem. Temperature too high. Probably triac

E005

Fuser web finished

E005

Fuser cleaner belt user up

E010

Drive

E010

Main drive problem

E011

Drive problem. Could be main motor, scan motor, cleaning web motor or duplex motor

E020

Toner empty sensor sees no toner added for 3 min probably toner feed problem

E050

Duplex problem

E203

Scan motor

E210

Lens home sensor or lens won't leave home

E240

DC controller board

E241

DC controller board

E242

DC controller board

E243

Operation panel board

E400

DC controller, ADF board or 24V

E500

DC controller, sorter board or 24V

E510

Finisher; feed motor, pulse sensor, finisher board

E520

Finisher; stack motor, stack tray sensor, finisher board

E530

Finisher; guide plate motor, stapler guide, finisher board

E531

Finisher; staple motor, staple sensor, finisher board


The surface temperature of the


Код ошибки

Описание

E000

The surface temperature of the fixing assembly upper roller fails to rise by a specified value within 90 sec after power-on. The surface temperature of the fixing assembly upper roller fails to reach 150C within 8 min after power on. The surface temperature of the fixing assembly upper roller fails to reach 180C within 5 min after it has reached 150C. The surface temperature of the fixing assembly upper roller falls below 50C in standby

E001

The surface temperature of the fixing assembly upper roller exceeds 250C

E005

The cleaning belt inside the fixing assembly has been taken up more than a specified length

E010

After generation of the main motor drive signal, two or more pulses are not received within 2 sec

E020

The accumulative time during which the toner supply signal (TSP) has been generated by the developing assembly reaches 3 min

E050

The holding tray home position signal (THP) is not generated within 4 sec while the holding tray motor drive signal (TMDP1,2) is being generated. The holding tray home position signal (THP) is generated 1 sec or more while the holding tray motor drive signal (TMDP1.2) is being generated

E13

The error detection circuit on the waste toner feed motor driver PCB has detected on overcurrent

E203

Input of two or more clock pulses is not received within 2 sec from the scanner motor drive signal is generated

E210

The lens home position signal (LHP) is not generated within 4.8 sec after the power switch or door switch has gone ON. The lens home position signal (LHP) is generate 2 sec or more

E240

An error has occurred in the microprocessor on the DC controller PCB

E243

An error has occurred in the communication between the microprocessor of the DC controller PCB and the microprocessor in the control panel

E710

An error has occurred in the communication between the DC controller PCB and the controller PCB of the option, and the DC controller has detected the error


The surface temperature of the


Код ошибки

Описание

E000

The surface temperature of the fixing assembly upper roller fails to rise by a specified value within 90 sec after power-on. The surface temperature of the fixing assembly upper roller fails to reach 150C within 8 min after power-on

E001

The surface temperature of the fixing assembly upper roller exceeds 250C

E005

The cleaning belt inside the fixing assembly has been taken up more than a specified length

E010

After generation of the main motor drive signal, two or more pulses are not received within 2 sec

E013

The error detection circuit on the waste toner feed motor driver PCB has detected an overcurrent

E020

The accumulative time during which the toner supply signal (TSP) has been generated by the developing assembly reaches 3 min*

E050

The holding tray home position signal (THP) is not generated within 4 sec while the holding tray motor drive signal (TMDP1, 2) is being generated. The holding tray home position signal (THP) is generated 1 sec or more while the holding tray motor drive signal (TMDP1, 2) is being generated

E203

Input of two or more clock pulses is not received within 2 sec from the scanner motor drive signal is generated

E210

The lens home position signal (LHP) is not generated within 4.8 sec after power switch or door switch has gone ON. The lens home position signal (LHP) is generate 2 sec or more

E240

An error has occurred in the microprocessor on the DC controller PCB

E243

An error has occurred in the microprocessor of the DC controller PCB and the microprocessor in the control panel

E710

An error has occurred in the communication between the DC controller PCB and the controller PCB of the option, and the DC controller has detected the error

E712

No communication is perceived from the RF controller PCB for 200 ms or more the communication is monitored at all times


An error is identified in


Код ошибки

Описание

E500

An error is identified in the communication between the sorter and copier

E510

The clock signal from the motor is absent for 250 ms or more

E513

The clock signal from the motor is absent for 250 ms or more

E530

The home position sensor (P17) fails to go OFF when an equivalent of 2560 pulses of the motor drive command has been generated

E531

The stapler unit swing sensor (MS9) fails to go ON within 500 ms after the motor drive command has been generated. MS9 fails to go back OFF within 1000 ms after it has gone ON

E540

The lead cam home position sensor (P12) fails to go OFF within 2000 ms after the motor drive command has been generated. P12 fails to go back ON within 2000 ms after it has gone OFF


No problem. Means that the


Код ошибки

Описание

C

No problem. Means that the machine is correcting the fuser film tracking

CC

Drum must be changed. Could be the drum serial number is identified by the logic as being non-compatible to that particular copier

E000

Low fuser temperature

E001

High fuser temperature

E002

High fuser temperature

E003

Erratic fuser temperature

E007

Fuser film off track and will not repair itself

E010

Main drive problem

E030

Counter problem

E064

Scan problem, or power supply

E202

Scan problem

E210

Lens drive problem or lens sensor

E220

Exposure lamp stays on or off

E240

DC controller (main board) or composite power supply

E261

Zero cross problem. Power frequency or composite power supply

E400

Communication problem between boards

E803

24 volt problem

E0

Fuser problem

H

Fuser overheat


Fuser thermistor, thermal fuse or


Код ошибки

Описание

E000

Fuser thermistor, heater, thermal fuse

E001

Fuser thermistor, or triac

E002

Fuser thermistor, thermal fuse or triac

E003

Fuser thermistor, heater, thermal fuse or triac

E004

Triac or fuser won't shut off

E007

Fuser film is off center or not driving properly

E010

Main motor drive problem

E030

Counter

E064

Composite power supply or main board

E202

Scan problem

E210

Lens drive problem

E220

Exposure lamp

E240

Main board or composite power supply

E261

Composite power supply or fluctuating power

E400

ADF communication problem to machine

E402

ADF belt motor drive

E404

ADF exit motor

E411

ADF document detect, or registration sensor or edge sensor

E500

Sorter communication problem

E510

Sorter drive problem

E530

Stapler guide bar motor

E531

Stapler swing motor

E540

Bin shift motor

E541

Bin motor drive problem

E710

Main board

E711

Main board

E712

Main board or communication problem with ADF

E717

Main board, asst. board

U0

Initializing. Sets all user modes to factory default settings

U1

Auto clear timer. Range 1-9. Each digit=1 minute

U2

Automatic power shut off timer

U3

Fine adjustment of zoom

U4

Auto cassette switching

U5

Sort or non-sort default

U6

Cleans document feeder pickup assembly

U7

CLEAR "replace drum"

U9

Auto exposure or manual exposure as default


Fuser problem. Low temperature. Lamp,


Код ошибки

Описание

E000

Fuser problem. Low temperature. Lamp, thermal switch, AC driver

E001

Fuser problem. High temperature. Triac, AC driver, pinched wire

E004

Fuser problem

E0053

Sorter

E030

Counter

E202

Scan

E210

Lens

E221

Exposure lamp regulator board, thermal fuse, exposure lamp

E400

Automatic document feeder

E500

Sorter

E710

DC controller


Canon C200D


Код ошибки

Описание

E000

Fuser thermistor, heater thermal fuse

E001

Fuser thermistor, or triac

E002

Fuser thermistor, thermal fuse or triac

E003

Fuser thermistor, heater, thermal fuse or triac

E004

Triac or fuser won't shut off

E007

Fuser film is off center or not driving properly. Might be able to reset in service mode 4-407

E010

Main motor drive problem

E030

Counter

E041

Paper deck motor, clutch or sensor

E064

Composite power supply or main motor board

E202

Scan problem. Motor sensor

E210

Lens drive problem

E220

Exposure lamp

E240

Main board or composite power supply

E260

Main board, power supply cooling fan or composite power supply

E261

Composite power supply or fluctuating power

E400

ADF communication to machine

E401

ADF pickup motor or sensor

E402

ADF belt motor drive

E403

ADF feed motor or slip sensor

E404

ADF exit motor

E411

ADF document detect, or registration sensor or edge sensor

E500

Sorter communication problem

E510

Sorter drive problem

E530

Stapler guide bar motor

E531

Stapler swing motor

E540

Bin shift motor

E541

Bin motor drive problem

E710

Main board (DC controller.)

E711

Main board (DC controller.)

E712

Main board or communication problem with ADF, or ADF main board

E717

Main board, assist board. "Replace drum": Drum waste toner is full, or drum has run 40,000 copies. Reset with user

E802

Composite power supply or DC controller

E901

Cassette feed unit board or cassette feed motor

E902

Horizontal registration problem. I think this refers to the duplex section

J1

Feed jam

J10

Duplex exit jam

J11

Vertical jam

J12

Vertical jam

J13

Vertical jam

J14

Vertical jam

J15

Deck jam

J2

Feed jam

J3

Separation area jam

J4

Separation area jam

J5

Exit jam

J6

Exit jam

J7

Sorter jam

J8

Door open jam

J9

Cassette jam

JA

Cassette jam

Jb

Cassette jam

JC

Cassette jam

Jd

Duplex feed jam

JE

Duplex exit jam

JF

Duplex registration jam



The main thermistor reading does


Код ошибки

Описание

E000

The main thermistor reading does not reach 40oC 14 sec after the fixing heater goes ON (fixing low temperature error)

E001

The main thermistor reading reaches 220°C or higher (fixing high temperature error)

E002

A start-up fault is detected under any of the following conditions of the main thermistor (start-up detection fault):

after exceeding 40°C, it fails to reach 60°C within 10 sec.

after exceeding 60°C, it fails to reach 80°C within 10 sec.

. . .

after exceeding 180°C, it fails to reach 195°C within 10 sec.

E003

After the end of the WAIT period, the main thermistor reading is 100°C or lower. In standby, the sub thermistor reading is 50°C or lower. (low temperature error in fixing temperature control)

E004

At time of initialization, the ZEROXI* signal of the power supply is not detected.

During temperature control, the ZEROXI* signal does not arrive for 3 sec continuously.

A short circuit is detected in the triac (ASIC; fixing temperature control drive circuit error).

Possible cause: Fixing assembly is faulty. (The main thermistor has an open circuit. The sub thermistor has an open circuit. The fixing heater has an open circuit. The power supply PCB is faulty. The DC controller PCB is faulty.)

Note: If E000 through E004 is indicated, the RAM on the image processor will retain the error memory of the fixing assembly after the power switch has been turned off an then on. Execute the following in service mode, and turn off and then on the power switch to clear the memory:

#7 PRINTER - #4 PRINTER RESET - YES=(*)

E010

A specific revolution is not detected from the main motor rotation detection signal (MLOK*), causing the signal to go '1' (main motor fault)

Possible cause: The main motor (M101) is faulty. The controller PCB is faulty.

E100

When the scanner motor is started up, the BD input signal does not arrive within a specific period of time.

When the scanner motor is started up, the motor rotation is too fast, and fails to reach a specific revolution within 20 sec at time of deceleration.

While the scanner motor is rotating at a specific speed, the BD input signal cycle is not within a specific range (±2%) for an equivalent of 10 mm (print distance).

While the scanner motor is rotating at a specific speed, the BD input signal cycle is not as indicated (±2%).

During the WMUPR period after the power switch has been turned on or the front cover/left cover has been opened/closed, the drum unit is absent.

Possible cause: The wiring is faulty (short circuit, open circuit). The laser scanner unit is faulty. The DC controller PCB is faulty. The drum unit is not installed.

E719

The communication between the card reader and the image processor PCB is disrupted.

Possible cause: The wiring is faulty (short circuit, open circuit). The card reader is faulty. The image processor PCB is faulty.

Note: If E719 is indicated, the fault in communication is retained by the RAM on the image processor even when the power switch has been turned off and then on; be sure to execute #12 CLEAR - CARD in service mode before making corrections.

E805

After the heat discharge fan drive signal is generated, the fan lock detection signal does not arrive for a specific period of time.

Possible cause: The fan wiring is faulty (short circuit, open circuit). The heat discharge fan (FM101) is fautly. The DC controller PCB is faulty.

Finisher Error Codes

E500

An error has occurred in the communication between the machine and the finisher twice continuously.

Possible cause: The harness to the finisher is faulty (disconnected connector, open circuit). The finisher controller PCB or the DC controller PCB is faulty.

E514

The stack delivery belt does not reach home position when the stack handling motor (M2) is driven for a specific time (CW; if the same condition occurs during stack delivery, a jam will be identified).

Possible cause: The stack handling motor (M2) is faulty. The stack delivery home position sensor (S8) is faulty. The connector is disconnected or has an operation circuit. The stack handling motor relay harness is faulty. The stack delivery belt is faulty. The finisher controller PCB is faulty.

E530

The rear aligning plate does not reach home position when the rear alignment motor (M4) has been driven for a specific time.

The rear aligning plate does not reach home position when the rear alignment motor (M4) has been driven for a specific time.

Possible cause: The rear alignment motor (M4) is faulty. The rear aligning plate home position sensor (S7) is faulty. The sensor connector is disconnected or has an open circuit. The rear alignment motor relay harness is faulty. The rear aligning plate is subjected to an abnormal load. The finisher controller PCB is faulty.

E531

The stapler does not leave the stapling home position sensor (S13) within 0.5 sec after the stapler motor (M6) is rotated CW.

The stapler does to return to the home position sensor (S13) within 0.5 sec after the stapler motor (M6) is driven CW and, in addition, it does not return to the sensor within 0.5 sec after the motor is driven CCW thereafter.

Possible cause: The stapler motor (M6) is faulty. The stapler home position sensor (SW1) is faulty. The stapler harness is faulty. The finisher controller PCB is faulty.

E537

The front aligning plate does not reach home position when the front aligning motor (M3) is driven for a specific time.

The front aligning plate does not leave home position when the front alignment motor (M3) is driven for a specific time.

Possible cause: The front alignment motor (M3) is faulty. The front aligning plate home position sensor (S6) is faulty. The sensor connector is disconnected or has an open circuit. The front alignment motor relay harness if faulty. The front aligning plate is subjected to an abnormal load. The finisher controller PCB is faulty.

E551

The delivery fan rotation signal (FNALCOK) does not arrive within 1 sec when the heat discharge fan drive signal (FANON) is sent.

Possible cause: The heat discharge fan (FM1) is faulty. The heat discharge fan relay harness is faulty. The heat discharge fan is subjected to an abnormal load. The finisher controller PCB is faulty.

E577

The return roller does not reach home position when the delivery motor (M1) is driven for a specific time. (If the same condition is detected while alignment takes place in the direction of feed, a jam will be identified)

Possible cause: The delivery motor (M1) on the finisher controller PCB is faulty. The return roller home position sensor (S3) is faulty. The connector is discontented or has an open circuit. The delivery motor relay harness is faulty. The return roller is faulty. The finisher controller PCB is faulty.

E580

The stack tray upper limit sensor (S1) goes ON while the stack tray up/down motor (M5) is in operation.

The clock signal of the stack tray up/down clock sensor (S9) is not detected 15 times or more within 0.8 sec while the stack tray up/down motor (M5) is in operation.

It does not reach the stack tray paper height sensor (S10) 2 sec after the stack tray up/down motor (M5) rotates for ascent.

It does not leave the stack tray power height sensor (S10) 2 sec after the stack tray up/down motor (M5) starts to rotate for descent.

Possible cause: The stack tray up/down motor (M5) is faulty. The stack tray paper height sensor (S10) is faulty. The sensor connector is disconnected or has an open circuit. The stack tray up/down clock sensor (SW9) is faulty. The sensor connector is disconnected or has an open circuit. The stack tray up/down motor is subjected to an abnormal load. The finisher controller PCB is faulty.

E585

The stack retaining lever does not reach home position when the stack handling motor (M2) has been driven for a specific time (at the start of motor CCW rotation). (If the same condition is detected during stack delivery, a jam will be identified)

Possible cause: The stack handling motor (M2) is faulty. The stack delivery lever home position sensor (S8) is faulty. The sensor connector is disconnected or has an open circuit. The stack handling motor relay harness is faulty. The stack retaining lever is faulty. The finisher controller PCB is faulty.


Canon NP


Код ошибки

Описание

E000

Fuser thermistor, heater thermal fuse

E001

Fuser thermistor, or triac

E002

Fuser thermistor, thermal fuse or triac

E003

Fuser thermistor, heater, thermal fuse or triac

E004

Triac or fuser won't shut off

E007

Fuser film is off center or not driving properly. Might be able to reset in service mode 4-407

E010

Main motor drive problem

E030

Counter

E041

Paper deck motor, clutch or sensor

E064

Composite power supply or main motor board

E202

Scan problem. Motor sensor

E210

Lens drive problem

E220

Exposure lamp

E240

Main board or composite power supply

E260

Main board, power supply cooling fan or composite power supply

E261

Composite power supply or fluctuating power

E400

ADF communication to machine

E401

ADF pickup motor or sensor

E402

ADF belt motor drive

E403

ADF feed motor or slip sensor

E404

ADF exit motor

E411

ADF document detect, or registration sensor or edge sensor

E500

Sorter communication problem

E510

Sorter drive problem

E530

Stapler guide bar motor

E531

Stapler swing motor

E540

Bin shift motor

E541

Bin motor drive problem

E710

Main board (DC controller.)

E711

Main board (DC controller.)

E712

Main board or communication problem with ADF, or ADF main board

E717

Main board, assist board. "Replace drum": Drum waste toner is full, or drum has run 40,000 copies. Reset with user

E802

Composite power supply or DC controller

E901

Cassette feed unit board or cassette feed motor

E902

Horizontal registration problem. I think this refers to the duplex section

J1

Feed jam

J10

Duplex exit jam

J11

Vertical jam

J12

Vertical jam

J13

Vertical jam

J14

Vertical jam

J15

Deck jam

J2

Feed jam

J3

Separation area jam

J4

Separation area jam

J5

Exit jam

J6

Exit jam

J7

Sorter jam

J8

Door open jam

J9

Cassette jam

JA

Cassette jam

Jb

Cassette jam

JC

Cassette jam

Jd

Duplex feed jam

JE

Duplex exit jam

JF

Duplex registration jam



Low temperature, thermoswitch, thermistor or


Код ошибки

Описание

E000

Low temperature, thermoswitch, thermistor or AC driver

E001

High temperature, thermistor, AC driver

E030

Counter

E202

Scan not returning home. Scan not leaving home

E221

Lamp regulator board

E400

Document feeder problem

E500

Sorter problem


has poor contact or an


Код ошибки

Описание

E000

?  The thermistor (TH1, TH2) has poor contact or an open circuit

?  The fixing heater (H1) has an open circuit

?  The thermal switch (TSW1) has turned on

?  The triac is faulty

?  The DC controller PCB is faulty

E001

?  The thermistor (TH1, TH2) has a short circuit

?  The triac is faulty

?  The DC controller PCB is faulty

E002

E003

The thermistor (TH1, TH2) has poor contact or an open circuit

?  The fixing heater (H1) has an open circuit

?  The thermal switch (TSW1) has turned on

?  The triac is faulty

?  The DC controller PCB is faulty

E004

?  The triac has a short circuit

?  The DC controller PCB is faulty

E010

?  The main motor (M1) is faulty

?  The DC controller PCB is faulty

E013

?  The waste toner feedscrew is locked

?  The waste toner feedscrew lock sensor (PS8) is faulty

?  The DC controller PCB is faulty

E030

?  The total copy counter has an open circuit

?  The DC controller PCB is faulty

E031

?  The accessories counter has an open circuit

?  The DC controller PCB is faulty

(E202)

No code indication. Keys are disabled

?  The scanner home position sensor (PS1) is faulty

?  The scanner motor (M2) is faulty

?  The DC controller PCB is faulty

E208

?  The mirror home position sensor (PS3) is faulty

?  The mirror motor (M4) is faulty

?  The DC controller PCB is faulty

E210

?  The lens home position sensor (PS2) is faulty

?  The lens motor (M3) is faulty

?  The DC controller PCB is faulty

E220

?  The lamp regulator PCB is faulty

?  The DC controller PCB is faulty

E261

?  The power supply frequency is faulty

?  The power supply PCB is faulty

E710

E711

?  The DC controller PCB is faulty

E712

?  The DC controller PCB is faulty

?  The ADF controller PCB is fault

?  The ADF cable is faulty

E717

?  The DC controller PCB is faulty

?  The Remote Diagnostic Device II PCB is faulty

E800

?  The auto power-off circuit has an open circuit

?  The DC controller PCB is faulty

E805

?  The exhaust fan (FM2, FM4) is faulty

?  The DC controller PCB is faulty

E821

?  The ozone filter is clogged

?  The cleaner thermistor (TH3) has poor contact or an open circuit

?  The DC controller PCB is faulty


Canon PC


Код ошибки

Описание

C

No problem. Means that the machine is correcting the fuser film tracking

CC

Drum must be changed. Could be the drum serial number is identified by the logic as being non-compatible to that particular copier

E000

Low fuser temperature

E001

High fuser temperature

E002

High fuser temperature

E003

Erratic fuser temperature

E007

Fuser film off track and will not repair itself

E010

Main drive problem

E030

Counter problem

E064

Scan problem, or power supply

E202

Scan problem

E210

Lens drive problem or lens sensor

E220

Exposure lamp stays on or off

E240

DC controller (main board) or composite power supply

E261

Zero cross problem. Power frequency or composite power supply

E400

Communication problem between boards

E803

24 volt problem

EO

Fuser problem

H

Fuser overheat

E000

Fuser thermistor, heater, thermal fuse

E001

Fuser thermistor, or triac

E002

Fuser thermistor, thermal fuse or triac

E003

Fuser thermistor, heater, thermal fuse or triac

E004

Triac or fuser won't shut off

E007

Fuser film is off center or not driving properly

E010

Main motor drive problem

E030

Counter

E064

Composite power supply or main board

E202

Scan problem

E210

Lens drive problem

E220

Exposure lamp

E240

Main board or composite power supply

E261

Composite power supply or fluctuating power

E400

ADF communication problem to machine

E402

ADF belt motor drive

E404

ADF exit motor

E411

ADF document detect, or registration sensor or edge sensor

E500

Sorter communication problem

E510

Sorter drive problem

E530

Stapler guide bar motor

E531

Stapler swing motor

E540

Bin shift motor

E541

Bin motor drive problem

E710

Main board

E711

Main board

E712

Main board or communication problem with ADF

E717

Main board, asst. board

U0

Initializing. Sets all user modes to factory default settings

U1

Auto clear timer. Range 1-9. Each digit=1 minute

U2

Automatic power shut off timer

U3

Fine adjustment of zoom

U4

Auto cassette switching

U5

Sort or non-sort default

U6

Cleans document feeder pickup assembly

U7

CLEAR "replace drum"

U9

Auto exposure or manual exposure as default

EO

Heater problem

E1

The heater film has gone off center. Turn machine off & on, make sure it's level etc

E2

Scan problme

E6

Exposure lamp or exposure lamp sensor

E000

Fuser problem

E001

Fuser problem

E010

Drive

E210

Zoom/lens/motor problem

E00

Heater, thermoswitch, exit sensor (Reset by jumping CP102 pins 1 & 2, or leave machine off for 20 seconds

E001

Shorted thermistor or high-temperature, Exit sensor

E010

Clock Pulse

E210

Zoom Lens Problem



Canon PC6


Код ошибки

Описание

E000

Fuser problem

E001

Fuser problem

E010

Drive

E210

Zoom/lens/motor problem


Reset by jumping CP102 pins


Код ошибки

Описание

E00

Heater, thermoswitch, exit sensor ( Reset by jumping CP102 pins 1 & 2, or leave machine off for 20 seconds

E001

Shorted thermistor or high-temperature, Exit sensor

E010

Clock Pulse

E210

Zoom Lens Problem


Что такое Девелопер?


Девелопер, он же носитель - ферромагнитный порошок, используемый в двухкомпонентных машинах для переноса тонера из DV-бокса (developer-box) на поверхность фотобарабана. Если быть совершенно точным, то на поверхность магнитного вала DV-бокса, а оттуда тонер уже под воздействием электростатических сил перетягивается на фотобарабан; причем сам девелопер, в силу своих магнитных свойств, остается на магнитном валу (прим. автора: здесь и далее используется терминология фирмы Sharp, у других разработчиков названия и некоторые детали могут немного отличаться, но суть от этого не меняется).

По структуре девелопер представляет собой мелкие шарики ферромагнитного материала. Это хорошо чувствуется, если потоптаться на рассыпанном порошке: нога заметно скользит. В дешевых аппаратах с одноразовыми картриджами девелопер представляет собой мелкие кристаллики неправильной формы. Разность в структуре объясняется тем, что в многоразовых картриджах использование дешевого "кристаллического" девелопера приведет к быстрому износу всех соприкасающихся с ним деталей (так называемый "абразивный эффект"). В одноразовых картриджах долгий срок жизни в принципе не нужен, здесь главное – себестоимость. Каждая частичка девелопера имеет специальное покрытие (жесткое резиноподобное для "одноразовых" девелоперов или полимерное стеклоподобное для "долгосрочных" порошков), благодаря которому при трении в процессе перемешивания девелопера его частички электризуются, что делает их способными удерживать также наэлектризованные частички тонера.

Кстати, теперь становится понятным, почему девелопер "пылит" в конце срока службы. Из-за длительного перемешивания он попросту "теряет" покрытие на своих частицах и уже не может удерживать тонер; причем при обедненной смеси этот процесс происходит быстрее. Кроме того, при длительном хранении, особенно при неблагоприятных условиях, в покрытии частичек девелопера образуются микротрещины, вследствие чего долго хранившийся порошок имеет более короткий срок службы.


Блок проявки в двухкомпонентых машинах состоит из двух бункеров (или боксов) – тонер-бокса и DV-бокса. При нормальных условиях в тонер-боксе находится тонер, в DV-боксе – смесь тонера и девелопера в определенной концентрации. При работе копира происходит расход тонера (на фотобарабане проявляется видимое изображение – отсюда и название "блок проявки") из DV-бокса; следовательно, меняется и концентрация тонера в DV-боксе. Когда содержание тонера в смеси снизится до определенного значения, происходит подмешивание (добавление) тонера из тонер-бокса в DV-бокс, пока не восстановится исходное, запомненное в памяти копира, значение концентрации.

Количество тонера в DV-боксе измеряется датчиком концентрации. Принцип его работы – изменение индуктивности при взаимодействии катушки с внешним ферромагнитным веществом. Опять же, если быть более точным, измеряется не количество тонера в смеси, а именно девелопера, т.к. тонер в основе своей полимер и на изменение индуктивности никак не влияет. Просто в смеси тонер как бы "разжижает" девелопер, отчего меняются ферромагнитные свойства последнего.

С теорией вроде как покончено, перейдем к практике.

Даже в заводских условиях практически невозможно с ювелирной точностью от партии к партии повторить параметры порошка, поэтому уже на заводе подбирается оптимальное соотношение смеси девелопер-тонер именно для данной партии девелопера, обеспечивающее требуемое качество изображения. И девелопер поставляется уже с добавленным в него тонером. Далее, уже при инсталляции девелопера на копире, считывается вот это "заводское" оптимальное значение концентрации и запоминается в памяти машины.

Из сказанного следует, что не рекомендуется делать следующее:

Копировать на машине с новым, только что засыпанным, девелопером до прогонки инсталляционной программы, ибо нарушается оптимальная заводская концентрация.

Прогонять программу инсталляции без нужды, т.е. без замены девелопера на новый, ибо одному Богу известно, какая концентрация имеется в текущий момент.


При включении копира (и в процессе работы, естественно) проверяется соответствие концентрации реальной и запомненной, и если тонера в DV-боксе мало (или машине кажется, что мало), то она пытается восстановить запомненную концентрацию, подмешивая тонер. Отсюда следует, что если Вам необходимо заменить девелопер, а в памяти копира по какой-либо причине записано неправильное значение концентрации (см. п.п.1 и 2 выше), либо имеется подозрение на неисправность датчика концентрации и его цепей, нужно успеть войти в сервисный режим до момента, когда машина начнет "восстанавливать" концентрацию. Либо, чтобы быть спокойным, можно вытрясти тонер-бокс, чтобы случайно не нарушить заводскую концентрацию.

Из сказанного следует и то, что для исправной и настроенной машины абсолютно все равно, инсталлируете ли Вы девелопер с пустым или заполненным тонер-боксом, т.к. в процессе прогона инсталляционной программы подмеса тонера не происходит. Точно так же для машины все равно, если Вы правильно проинсталлируете девелопер, а потом сделаете несколько десятков копий с пустым тонер-боксом; главное, что машина уже запомнила нужное значение. Как только Вы добавите тонер (или вставите тубу с тонером и т.д.), копир сам подмешает нужное ему количество.

Все вышесказанное верно для машин с датчиками концентрации. Есть копиры, где таких датчиков нет, а используются другие методы для определения количества подмешиваемого тонера в процессе работы. Наверняка у других производителей могут применяться и другие методики инсталляции носителя. Но про это пусть рассказывают представители этих брэндов, у них это лучше получится.

P.S. На последних цифровых копирах формата А4 и младшего сегмента формата А3 Sharp отказался от программы инсталляции девелопера, т.е. для начала работы девелопер просто засыпается в бункер без каких-либо дополнительных операций. Связано это с упрощением процедуры запуска аппаратов, т.к. предназначены они в первую очередь для индивидуальных пользователей и малых офисов.Да и фабрика в состоянии контролировать стабильность качества рабочей смеси в достаточной степени.

Для старших сегментов программная инсталляция сохранилась, т.к. требования к качеству копий выше.

http://www.repair-printer.ru/viewtopic.php?t=2809